Banks are located in various corners of the city and belong to the national prevention units. They have the characteristics of diverse scale, numerous important facilities, complex entry and exit personnel, and wide-ranging management. As the main place of currency circulation in today's society and an important link in the operation of the national economy, it serves various industries in China with its unique functions and advanced technology. In order to ensure the normal operation of the bank's security system, it must have efficient security and stability.
In order to ensure the stable operation of equipment within the bank, according to the mandatory industry standard "GA38-2021 Bank Security Prevention Requirements" of the Ministry of Public Security, requirement 5.10 proposes that self-service devices and security technology prevention systems of self-service banks should be equipped with uninterrupted backup power supply, and the backup power supply should ensure that the video surveillance system works normally for no less than 2 hours after the mains power is cut off; The normal working time of the alarm system should not be less than 8 hours; If the lock of the population control system adopts power-off opening mode, the normal working time should not be less than 48 hours. When the mains power is cut off, the system should send a power outage alarm message to the networked monitoring center.
HT-SDPS-AC/08/S
● 2U rack mounted design, capable of being installed in standard cabinets.
● Remote/manual switching of ports can be achieved, and the output status of all output ports is visible at the front panel indicator light and the upper computer software.
● Automatic switching between mains power and UPS power supply, with a switching time of less than 50 milliseconds.
● After a power outage, UPS power supply capacity can be allocated according to scheduled settings.
● 8-channel AC 220V output.
● The backup time for each circuit can be set through the LCD screen and control buttons.
● After a power outage, the system sends a power outage alarm message to the networked monitoring center.
● When the host is started, the 8 output ports start the power supply one by one in order to avoid the impact on the equipment caused by simultaneous power on and ensure the stability of the power system.
● 3 switch outputs, UPS power-off linkage output K1, mains power-off linkage output K2, overvoltage, overcurrent, and overtemperature linkage output K3. Two switch inputs and one 485 interface.
No. | Project | Parameters & performance |
1 | Network interface | 1 standard RJ45 input interface |
2 | Network protocol | TCP/IP、UDP |
3 | Power output | 8 channels, AC 220V output |
4 | Voltage and current display | Support, LED display |
5 | Product size | 435×400×90mm(L*W*H) |
6 | Operation temperature | -10℃~55℃ |
7 | Working humidity | 10%~90% |
8 | Rated voltage | AC 180-250V |
9 | Total current | ≤25A |
10 | Maximum power consumption | ≤ 5500W |