Hengtong DCU2000 64 Doors Access Control System

      Hengtong DCU2000 Doors Access Control System is made up of software of management center, controllers, door modules, readers or fingerprint scanners, magnetic contacts, open door buttons, locks and alarms. One management center will connect several 485 bus with each having 16 controllers connected but unlimited by TCP/IP, each controller will connect and control 64 doors, each door module will connect and control a door lock, a readers or fingerprint scanners, a magnetic contacts, an open door buttons and an alarm.

      The strong control and management functions will offer you an excellent service.

1¡¢Features and Functions:

         · Weigand 26 card-reader and fingerprint scanner supported;

         · A controller will connect and control 2 unilateral doors, 1 bidirectional door or 2 interlocking

            doors for preventing a tailer;

         · Expansion supported, 62 door modules will be connected to a controller, each will control one door

            by connecting a lock, a magnetic contact, an alarm, a fingerprint scanner or card-reader with an

            open door button on it, 64 doors will be controlled at most;

         · RS485 and TCP/IP interfaces offered, a management center can connect several 485 bus with each

            having 16 controllers, and unlimited via TCP/IP;

         · Bidrectional open doors setup, any two doors will be set to be bidrectional open doors for

            anti-latency, and any several doors will be set to be an anti-latency zone, 8 anti-latency

            zones will be set;

         · Any 2 doors will be set to be interlocking doors for preventing a tailer;

         · Card and password, grouping case open and access group setting;

         · Arm/Disarm card setup, swiping invalid when a door in the armed state;

         · Armed/Disarmed by keypad with arm indicator;

         · 15 schedules set with weekdays, 4 intervals a day, 256 holidays control setup;

         · Door normal opened setup, closed when time out and in holiday;

         · Open button for opening the door from in-door, enable setup on the management center;

         · Alarm when the door opened overtime, abnormal open and swiping card error five times. Alarm and

            exit the system when inputting the error password three times to the management center;

         · Duress ID setup, alarm when open the door under duress;

         · Alarm when a controller tampered;

         · Fire control, press the fire control button to open some preset doors for evacuating or close

            some preset doors to isolate fire;

    · Remote control: Management center will remotely control some door or all doors opened or closed in

            emergency, arm or disarm as well.

         · Double open/Double close buttons for B1/B2 doors directly connected to PCB of the controller in

            emergency.

         · Grouping case open setup, for some period of time on the special occasion only several cardholders

           must swipe their card at the same time, the door can be opened.

         · Alarm output for connecting the light¡¢alarm or record equipment. 3 outputs supported, 1 for B1 door,

           1 for B2 door, 1 for expansion door modules, and every door module has an alarm output.

         · Small exterior, the door module with the open door button can install on the standard 86¡Á86mm case.

         · 5000 pieces of user information will be saved.

         · 20000 pieces of action record (in, out, alarm and reset) will be saved.

2¡¢System Connection

    3¡¢Interface of the management center

    


   4¡¢Technical specification

Items
Specification
Data protection
Yes
Reader format
Weigand 26
Door status control
Yes
Open door button
Disable selectable
Door lock
Normal open and normal close selectable
Alarm when door opened overtime
1-59 seconds selectable
Transmission

RS185/232£¬TCP/IP selectable

Transmission speed
9600Bps
Transmission distance
RS485¡Ü1200m
Door normal open configuration
4 interval a day
Error alarm
Alarm if 5 error swiping or 3 password error
Double open
For B1¡¢B2 doors£¨address 0¡¢1£©
Double close For B1¡¢B2 doors£¨address 0¡¢1£©
Fire control Emergency button for preset doors open and close
Group open Configuratable
Max quantity of the card issued ¡Ü5000
Anti-tailer interlocking doors Any two doors
Bidirectional interlocking doors Any two doors
Anti-latency 8 zones for configuration
Card and password open Selectable for configuration
Arm/Disarm cards configuration For any card, any door
Keypad arm/disarm For B1 door£¨address 0£©
Armed indicator For B1 door£¨address 0£©
Tamper alarm For controller
Alarm under duress Configuratable
Alarm output For B1, B2 door, 485bus, Extension door module
Schedule and holiday control 15 working schedules and 256 holidays control setup
User information storage 5000 pieces
Information storage 20000 pieces
Controller number 16 controllers can be connected to a RS485 bus
Controlled door number 2 doors extendable up to 64 doors
Controller dimension 350¡Á270¡Á75mm
Main board size 180¡Á110mm
Relative humidity ¡Ü90%
Working temperature 0¡æ-50¡æ
Power supply AC220V/DC12V¡À15%
Power consumption
¡Ü2W

 

 